
2-6 Radical-7 Color Display Signal Extraction Pulse Oximeter Operator’s Manual Radical-7 Color Display Signal Extraction Pulse Oximeter Operator’s Manual 2-7
system description
2
HANDHELD BACK PANEL
The Handheld back panel features the interconnection to the Docking Station, an accessory
mount for the pole clamp accessory and access to the Handheld battery pack.
1
DOCKING
STATION
CONNECTOR
The Radical-7 Handheld interfaces with the Docking Station
through this connector.
2
POLE CLAMP
ACCESSORY
HOLDER
The optional Pole Clamp accessory attaches to this holder.
See the Directions for Use of the Pole Clamp accessories
for attachment instructions.
3
BATTERY PACK
The Radical-7 Handheld is powered by a NiMH battery
located in this compartment. For battery care and replace-
ment please see Section 9, Replacing the Batteries.
1251 0000 536
MEDICAL ELECTRICAL EQUIPMENT
UL 2601-1/CAN/CSA C22.2 No. 601.1
80FK
11328/2269M-0805
Covered by one or more of the following U.S. Patents: RE38,492,
RE38,476, 6,850,787, 6,826,419, 6,816,741, 6,699,194,
6,684,090, 6,658,276, 6,654,624, 6,650,917, 6,643,530,
6,606,511, 6,584,336, 6,501,975, 6,463,311, 6,430,525,
6,360,114, 6,263,222, 6,236,872, 6,229,856, 6,206,830,
6,157,850, 6,067,462, 6,011,986, 6,002,952, 5,919,134,
5,823,950, 5,769,785, 5,758,644, 5,685,299, 5,632,272,
5,490,505, 5,482,036, international equivalents, or one or more
of the patents referenced at www.masimo.com/patents.
Products containing Satshare® feature are also covered by
U.S. Patent 6,770,028. Other patents pending.
1
2 3
system description
2
MAIN SCREEN TREND GRAPH DISPLAY
The Radical-7 Pulse CO-Oximeter provides a Trend Graph display function which allows the
user to quickly check the trend of each parameter by allowing to step through and selecting
the desired parameter. This is done by repeatedly pressing down on the Trend Graph control
button. Once the parameter is selected, the numeric value is highlighted and the selected
parameter is displayed above the trend graph.
1
The first top line of the trend graph display shows the time scale of the trend graph
followed by the selected parameter. The parameter’s numeric value is highlighted.
2
The second top line of trend graph display shows the minimum, average and maxi-
mum measurement of the selected parameter contained in the displayed data set
(excluding zero measurements).
3
The Trend Graph control button initates the trend graph display. Repeatedly press-
ing down on the button will step through each parameter, highlighting the numeric
value and displaying the parameter above the trend graph.
4
The lines on the trend graph indicate the minimum and maximum values of the
parameter.
5
The trend graph shows the desired parameter measurements displayed versus
time and the accuracy range
1
Signal Extraction Pulse CO-Oximeter
Masimo rainbow SET
99
85
Sp0
2
140
50
BPM
PI
SpMet
SpCO
3.0
0.3
50
5
10/11/06 12:23:11am
100
50
1 Hr Trend 88 95 97
2
3
4
5
Comentarios a estos manuales